Preface |
|
|
|
Chapter 1 |
|
INTRODUCTION |
|
|
pdf
1.1
(302 KB)
|
Purpose |
|
|
1.1 |
Intended Audience |
|
|
1.1 |
Regional Applicability |
|
|
1.1 |
Limitations |
|
|
1.1 |
Acknowledgements |
|
Chapter 2 |
|
BEHAVIOR OF NONSTRUCTURAL COMPONENTS |
|
2.1 |
|
Definitions |
|
|
2.1.1 |
Structural Components |
|
|
2.1.2 |
Nonstructural Components |
|
|
2.1.3 |
Relative Costs |
|
2.2 |
|
Causes of Nonstructural Components |
|
|
2.2.1 |
Inertial Forces |
|
|
2.2.2 |
Building Deformations |
|
|
2.2.3 |
Building Separations |
|
|
2.2.4 |
Nonstructural Interaction |
|
2.3 |
|
Extent of Nonstructural Damage |
|
2.4 |
|
Importance of Nonstructural Damage |
|
|
2.4.1 |
Life Safety (LS) |
|
|
2.4.2 |
Property Loss (PL) |
|
|
2.4.3 |
Functional Loss (FL) |
|
2.5 |
|
Common Types of Nonstructural Earthquake Damage |
|
|
2.5.1 |
Life Safety |
|
|
2.5.2 |
Property Loss |
|
|
2.5.3 |
Functional Loss |
|
Chapter 3 |
|
SURVEY AND ASSESSMENT PROCEDURES FOR EXISTING BUILDING |
|
3.1 |
|
Survey of Nonstructural Components |
|
|
3.1.1 |
Survey Forms |
|
3.2 |
|
Estimating Seismic Risk |
|
|
3.2.1 |
Estimating Seismic Shaking Intensity |
|
|
3.2.2 |
Estimating Seismic Risk Rating |
|
|
3.2.3 |
Assigning Priority Ratings |
|
|
3.2.4 |
Application of Nonstructural Guidelines |
|
Chapter 4 |
|
NONSTRUCTURAL RISK REDUCTION FOR EXISTING BUILDING |
|
4.1 |
|
Program Objectives and Scope |
|
|
4.1.1 |
Voluntary vs. Mandatory Risk Reduction |
|
|
4.1.2 |
Performance-Based Design Concepts |
|
|
4.1.3 |
Legal Considerations |
|
4.3 |
|
Project Planning and Implementation Strategies. |
|
|
4.3.1 |
Integration with Maintenance Programs |
|
|
4.3.2 |
Integration with Remodeling |
|
|
4.3.3 |
Phased or Incremental Upgrading |
|
|
4.3.4 |
Integration with Purchasing |
|
4.4 |
|
Responsibility and Program Management |
|
|
4.4.1 |
Responsibility |
|
|
4.4.2 |
Sustaining Protection |
|
|
4.4.3 |
Program Evaluation |
|
4.5 |
|
Cost Benchmarks-Examples |
|
|
4.5.1 |
Example 1 – Manufacturing Facility |
|
|
4.5.2 |
Example 2 – School district |
|
|
4.5.3 |
Example 3 – California Hospital |
|
Chapter 5 |
|
NONSTRUCTURAL RISK REDUCTION FOR NEW BUILDINGS |
|
5.1 |
|
Program Objectives and Scope |
|
|
5.1.1 |
Voluntary vs. Mandatory Risk Reduction |
|
|
5.1.2 |
Performance-Based Design Concepts |
|
5.2 |
|
Design Considerations |
|
5.3 |
|
Building Code Requirements |
|
|
5.3.1 |
2012 Edition of the International Building Code (IBC 2012) |
|
|
5.3.2 |
Enforcement of Code Requirements |
|
|
5.3.3 |
Requirements for Contents |
|
|
5.3.4 |
Other Standards and Protocols |
|
|
5.3.5 |
Validation and Refinement of Code Requirements |
|
5.4 |
|
Responsibility and Project Management |
|
|
5.4.1 |
Example: Responsibility Matrix |
|
|
5.4.2 |
Example: Seismic Code Block, Saint Louis County, Missouri |
|
|
Subcategory |
Example |
Component Type |
Type of Detail |
SECTION 6.3 |
|
ARCHITECTURAL COMPONENTS |
|
6.3.1 |
|
Exterior Wall Components |
|
|
pdf
6.3.1.1
(4.10 MB)
|
Adhered veneer |
ER |
|
pdf
6.3.1.2
(2.58 MB)
|
Anchored veneer |
ER |
|
pdf
6.3.1.3
(3.97 MB)
|
Prefabricated panels |
ER |
|
pdf
6.3.1.4
(3.25 MB)
|
Glazed exterior wall system |
ER |
|
pdf
6.3.1.5
(4.02 MB)
|
Glass Blocks |
ER |
6.3.2 |
|
Interior Partitions |
|
|
pdf
6.3.2.1
(4.37 MB)
|
Heavy |
ER |
|
pdf
6.3.2.2
(3.97 MB)
|
Light |
ER |
|
pdf
6.3.2.3
(4.15 MB)
|
Glazed |
ER |
6.3.3 |
|
Interior Veneers |
|
|
pdf
6.3.3.1
(1.95 MB)
|
Stone and Tile |
ER |
6.3.4 |
|
Ceilings |
|
|
pdf
6.3.4.1
(6.15 MB)
|
Suspended lay-in tile ceiling systems |
PR |
|
pdf
6.3.4.2
(5.15 MB)
|
Ceilings applied directly to structure |
NE |
|
pdf
6.3.4.3
(4.29 MB)
|
Suspended heavy ceilings |
PR |
6.3.5 |
|
Parapets and Appendages |
|
|
pdf
6.3.5.1
(2.47 MB)
|
Unreinforced masonry parapets |
ER |
6.3.6 |
|
Canopies, Marquees, and Signs |
|
|
pdf
6.3.6.1
(1.53 MB)
|
Canopies, marquees, and signs |
ER |
6.3.7 |
|
Chimneys and Stacks |
|
|
pdf
6.3.7.1
(1.82 MB)
|
Unreinforced masonry chimney |
ER |
6.3.8 |
|
Stairways |
|
|
pdf
6.3.8.1
(3.84 MB)
|
Stairways |
ER |
6.3.9 |
|
Freestanding Walls and Fences |
|
|
pdf
6.3.9.1
(2.68 MB)
|
Freestanding masonry wall or fence |
PR |
SECTION 6.4 |
|
MECHANICAL, ELECTRICAL, & PLUMBING (MEP) COMPONENTS |
|
6.4.1 |
|
Mechanical Equipment |
|
|
pdf
6.4.1.1
(3.53 MB)
|
Boilers, furnaces, pumps, and chillers (HVAC wet side) |
ER |
|
pdf
6.4.1.2
(1.66 MB)
|
General manufacturing and process machinery |
ER |
|
pdf
6.4.1.3
(2.25 MB)
|
HVAC equipment with vibration isolation |
ER |
|
pdf
6.4.1.4
(2.20 MB)
|
HVAC equipment without external vibration isolation |
ER |
|
pdf
6.4.1.5
(3.75 MB)
|
HVAC equipment suspended in-line with ductwork |
ER |
|
pdf
6.4.1.6
(1.36 MB)
|
Suspended equipment |
ER |
6.4.2 |
|
Storage Tanks and Water Heaters |
|
|
pdf
6.4.2.1
(4.39 MB)
|
Structurally supported tanks and vessels |
ER |
|
pdf
6.4.2.2
(3.72 MB)
|
Flat bottom tanks and vessels |
ER |
|
pdf
6.4.2.3
(4.85 MB)
|
Compressed gas cylinders |
NE |
|
pdf
6.4.2.4
(1.02 MB)
|
Water heaters |
PR |
6.4.3 |
|
Pressure Piping |
|
|
pdf
6.4.3.1
(6.38 MB)
|
Suspended pressure piping |
ER |
|
pdf
6.4.3.2
(1.88 MB)
|
In-line valves and pumps |
ER |
|
pdf
6.4.3.3
(3.23 MB)
|
Flexible connections, expansion joints, and seismic separations sepasepaseparati separations |
ER |
|
pdf
6.4.3.4
(4.78 MB)
|
Pipe risers |
ER |
|
pdf
6.4.3.5
(3.54 MB)
|
Floor-mounted supports |
ER |
|
pdf
6.4.3.6
(2.72 MB)
|
Roof-mounted supports |
ER |
|
pdf
6.4.3.7
(3.53 MB)
|
Wall-mounted supports |
ER |
|
pdf
6.4.3.8
(4.53 MB)
|
Penetrations |
ER |
6.4.4 |
|
Fire Protection Piping |
|
|
pdf
6.4.4.1
(4.98 MB)
|
Suspended fire protection piping |
ER |
6.4.5 |
|
Fluid Piping, not Fire Protection |
|
|
pdf
6.4.5.1
(6.26 MB)
|
Hazardous materials piping |
ER |
|
pdf
6.4.5.2
(3.66 MB)
|
Nonhazardous materials piping |
ER |
6.4.6 |
|
Ductwork |
|
|
pdf
6.4.6.1
(4.07 MB)
|
Suspended ductwork |
ER |
|
pdf
6.4.6.2
(1.65 MB)
|
Air diffusers |
NE, ER |
6.4.7 |
|
Electrical and Communications Equipment |
|
|
pdf
6.4.7.1
(3.08 MB)
|
Control panels, motor control centers, and switchgear |
ER |
|
pdf
6.4.7.2
(1.63 MB)
|
Emergency generator |
ER |
|
pdf
6.4.7.3
(4.66 MB)
|
Transformers |
ER |
|
pdf
6.4.7.4
(2.33 MB)
|
Batteries and battery rack |
ER |
|
pdf
6.4.7.5
(4.52 MB)
|
Photovoltaic (PV) power systems |
ER |
|
pdf
6.4.7.6
(4.09 MB)
|
Communications Antennae |
ER |
6.4.8 |
|
Electrical and Communications Distribution Equipment |
|
|
pdf
6.4.8.1
(2.90 MB)
|
Electrical raceways, conduit, and cable trays |
ER |
|
pdf
6.4.8.2
(1.66 MB)
|
Electrical distribution panels |
ER |
6.4.9 |
|
Light Fixtures |
|
|
pdf
6.4.9.1
(4.83 MB)
|
Recessed lighting |
PR |
|
pdf
6.4.9.2
(2.18 MB)
|
Surface-mounted lighting |
PR |
|
pdf
6.4.9.3
(1.78 MB)
|
Pendant light fixtures |
NE |
|
pdf
6.4.9.4
(2.80 MB)
|
Heavy light fixtures |
NE |
6.4.10 |
|
Elevators and Escalators |
|
|
pdf
6.4.10.1
(1.65 MB)
|
Hydraulic elevator |
ER |
|
pdf
6.4.10.2
(1.48 MB)
|
Traction elevator |
ER |
|
pdf
6.4.10.3
(1.19 MB)
|
Escalators |
ER |
6.4.11 |
|
Conveyors |
|
|
pdf
6.4.11.1
(2.63 MB)
|
Conveyors |
ER |
SECTION 6.5 |
|
FURNITURE, FIXTURES, & EQUIPMENT (FF&E) COMPONENTS |
|
6.5.1 |
|
Storage racks |
|
|
pdf
6.5.1.1
(5.67 MB)
|
Light duty shelving |
NE, ER |
|
pdf
6.5.1.2
(7.35 MB)
|
Industrial storage racks |
ER |
6.5.2 |
|
Bookcases, Shelving |
|
|
pdf
6.5.2.1
(2.70 MB)
|
Bookshelves |
NE |
|
pdf
6.5.2.2
(3.55 MB)
|
Library and other shelving |
ER |
6.5.3 |
|
Computer and Communication Equipment |
|
|
pdf
6.5.3.1
(6.05 MB)
|
Computer access floors and equipment |
ER |
|
pdf
6.5.3.2
(1.87 MB)
|
Computer and communication racks |
NE |
|
pdf
6.5.3.3
(852 KB)
|
Desktop computers and accessories |
NE |
|
pdf
6.5.3.4
(1.42 MB)
|
Televisions and video monitors, wall-mounted |
NE |
6.5.4 |
|
Hazardous materials storage |
|
|
pdf
6.5.4.1
(1.93 MB)
|
Hazardous materials storage |
NE |
6.5.5 |
|
Miscellaneous FF&E |
|
|
pdf
6.5.5.1
(3.24 MB)
|
File cabinets |
NE |
|
pdf
6.5.5.2
(2.05 MB)
|
Demountable partitions |
NE |
|
pdf
6.5.5.3
(2.11 MB)
|
Miscellaneous furniture and fixtures |
NE |
6.5.6 |
|
Miscellaneous Contents |
|
|
pdf
6.5.6.1
(3.01 MB)
|
Shelf-mounted items |
NE |
|
pdf
6.5.6.2
(1.73 MB)
|
Desktop, countertop items |
NE |
|
pdf
6.5.6.3
(3.36 MB)
|
Fragile artwork |
NE |
|
pdf
6.5.6.4
(1.20 MB)
|
Fire extinguisher and cabinet |
NE |
SECTION 6.6 |
|
INSTALLATION NOTES, SAFETY WARNINGS, AND ADDITIONAL GUIDELINES |
|
|
pdf
6.6.1
(161 KB)
|
Positive Connections |
|
|
6.6.2 |
Typical Wall Attachment Details |
|
|
6.6.3 |
Typical Floor and Ceiling Attachment Details |
|
|
6.6.4 |
Typical Shelf or Countertop Attachment Details |
|
|
6.6.5 |
Purchasing |
|
|
6.6.6 |
Patching, Painting, and Corrosion Protection |
|
|
6.6.7 |
Safety Percautions |
|
|
6.6.8 |
Electrical Danger Warings and Guidelines |
|